أجهزة كهربائية — مجاري كابلات · أقفال كابلات · أطراف نحاسية

طريق الكابلات — ثلاث درجات حسب الخامة
Every building hides kilometers of cable trays above its ceilings. Heat up there reaches 50°C+ and dust never sleeps. Three grades:
| Economy | Pre-galvanized sheet · indoor dry zones |
| Standard ★ | Hot-dip galvanized after fabrication — rooftop & shafts ready — best seller |
| Premium | SS304 · coastal & chemical plants |

ما يُفسد المجري: الصدأ · الانحناء · الغبار
Thin pre-galvanized sheet rusts through at the cut edges first — zinc on the surface never protects the cut. Under-gauge steel sags under cable load → trays become dips that collect dust and water. Loaded joints shear thin splice plates → sections drop. Sheet thickness and zinc mass decide everything.

المواصفات
| Width | 50–600 mm (typ. 100–400) |
| Height | 50 / 100 mm |
| Length | 2.5 / 3 m per section |
| Fittings | Elbows · tees · risers · covers · splice plates |

الخامات والتصنيع
| Economy | Pre-galvanized sheet (zinc both faces) |
| Standard ★ | HDG after fabrication — cut edges coated too |
| Premium | SS304 laser-cut |
| Edge | Rounded return flange — no sharp edge on cables |

خطوات التركيب
① Hang threaded rods per span table (≤1.5 m typical). ② Level the runs before loading. ③ Bolt splice plates with the supplied fasteners — full torque. ④ Bond each joint with an earth strap. ⑤ Lay cables, fit covers in dusty zones.
الشهادات والمعايير — وثائق الجودة
| Product | HDG Cable Tray 100×50 mm |
| Standard | IEC 61537 system requirements |
| Load | Span load test — no permanent set |
| Corrosion | ISO 9227 neutral salt spray |
| Result | PASS — report copy with every shipment |
| Product | Cable Tray series (PG / HDG / SS304) |
| Market | KSA (SASO-ready) · UAE (ECAS-ready) |
| Scope | Declared conformity + CoC documentation |
| Status | Documentation pack on request |
| Inspection | Third-party PSI (independent agency) |
| Timing | 80% packed, before loading |
| AQL | 0 critical / 2.5 major / 4.0 minor |
| Sampling | ISO 2859-1 Level II |
| Result | ACCEPTED — report with photos |

نقطة دخول الكابل إلى اللوحة — ثلاث درجات
Every cable enters a panel through one gland. That single joint decides whether dust and moisture stay out of the box. Three grades:
| Economy | PA66 nylon (UL94 V-0) · indoor panels |
| Standard ★ | Nickel-plated brass · IP68 — best seller |
| Premium | SS304 · coastal & chemical panels |

ما يُفسد الجلند: تصلّب المطاط · الصدأ · الارتخاء
Heat-hardened rubber seals crack → fine dust pumps into the panel with every temperature cycle → terminals corrode, breakers trip. Cheap zamak bodies wear their threads round → gland never torques down. Loose lock nuts let cables tug out . Brass body + real NBR seal decide everything.

المواصفات
| Thread | M12 / M16 / M20 / M25 / M32 ×1.5 |
| Cable OD | 3–6.5 / 5–10 / 6–12 / 13–18 / 18–25 mm |
| Panel hole | Per thread size (e.g. M20 = Ø20.5) |
| Rating | IP68 · −40 to +120 °C (brass) |

الخامات والتصنيع
| Economy | PA66 nylon · flame-retardant |
| Standard ★ | Brass, nickel-plated · NBR seal |
| Premium | SS304 · FKM seal option |
| Certs | CE · UL · RoHS · REACH (per Difvan spec) |

خطوات التركيب
① Drill the panel hole per thread size. ② Insert gland, tighten the lock nut from inside — full torque. ③ Pass the cable, slide the seal and clamping ring. ④ Torque the dome cap until the seal grips — cable must not twist or pull out. ⑤ Unused holes: always plugged.
الشهادات والمعايير — وثائق الجودة
| Product | Brass Cable Gland M20×1.5 |
| Standard | EN 50262 (gland standard) |
| Ingress | IP68 dust & immersion test |
| Strain | Cable pull-out / torque test |
| Result | PASS — report copy with every shipment |
| Product | Cable Gland series (PA66 / brass / SS304) |
| Market | KSA (SASO-ready) · UAE (ECAS-ready) |
| Scope | Declared conformity + CoC documentation |
| Status | Documentation pack on request |
| Inspection | Third-party PSI (independent agency) |
| Timing | 80% packed, before loading |
| AQL | 0 critical / 2.5 major / 4.0 minor |
| Sampling | ISO 2859-1 Level II |
| Result | ACCEPTED — report with photos |

نقطة وصول القدرة إلى الناقص — ثلاث درجات
Every power cable ends in one lug, bolted to the busbar. That joint carries the full current — 24/7 in a 50°C cabinet. Three grades:
| Economy | Thin-wall barrel · light-duty circuits |
| Standard ★ | T2 copper, thick-wall, hot-tinned — best seller |
| Premium | Standard + insulated sleeve kits |

ما يُفسد الطرف: أكسدة · شقوق · غير قياسي
Scrap-copper or copper-clad aluminum bodies run hot → oxidation bakes the joint black → resistance climbs, heat climbs — a loop that ends in melted insulation. Thin zinc-wash tin plating flakes off → contact resistance up. Thin barrels crack at crimp → strands break loose. Non-standard palms won't match the bolt .

المواصفات
| Series | DTL-1 / DTL-2 bolt-type lugs |
| Cable range | 16 – 1000 mm² |
| Body | T2 copper, tin-plated |
| Bolt | Matched hole per size |

الخامات والتصنيع
| Economy | Thin-wall, flash-tinned |
| Standard ★ | T2 copper · thick wall · hot-dip tinned |
| Premium | + color-coded insulated sleeves |
| Check | Inspection window on barrel |

خطوات التركيب
① Strip the cable — length equals barrel depth. ② Crimp with the matched die — full compression, check via the window. ③ Bolt to the busbar with washer and spring washer, rated torque. ④ Never reuse a crimped lug. ⑤ In hot cabinets, re-torque after first thermal cycle.
الشهادات والمعايير — وثائق الجودة
| Product | DTL Copper Cable Lug (tin-plated) |
| Material | Copper purity & plating thickness cert |
| Standard | IEC 61238-1 connector requirements |
| Crimp | Tensile pull-out test |
| Result | PASS — report copy with every shipment |
| Product | Copper Terminal series (16–1000 mm²) |
| Market | KSA (SASO-ready) · UAE (ECAS-ready) |
| Scope | Declared conformity + CoC documentation |
| Status | Documentation pack on request |
| Inspection | Third-party PSI (independent agency) |
| Timing | 80% packed, before loading |
| AQL | 0 critical / 2.5 major / 4.0 minor |
| Sampling | ISO 2859-1 Level II |
| Result | ACCEPTED — report with photos |